Skip to content
S&B Tech

Transformers

PCB Mount Transformers

Also listed as PCB Type Transformers

0.35–55 VA, EE and EI cores, 230 V primary, EN 61558

PCB mount transformers are through-hole, chassis-free mains transformers that solder directly to the board, providing galvanic isolation and voltage step-down for the primary circuit. The current range spans 0.35 to 55 VA on EE and EI cores, in single- and double-bobbin construction, across the EE20, EI30, EI38, EI42, EI48, EI54, EI60, and EI66 sub-series — with the withdrawn EI78, EI84, and EI96 series reaching 220 VA still documented for designs already using them. Every winding runs from a single 230 V primary and offers 4 to 24 V secondaries, single or dual. Bobbins are available in standard, eared (K/KK), or VL flying-lead cover styles, so the same electrical winding can be specified to match board clearance and mounting-hole layout. Because the part solders directly to the board, footprint and pin spacing are as much a selection criterion as VA rating and turns ratio.

Insulation

Insulation and impregnation are specified as air, oven-dried varnish, polyurethane coating, or epoxy potting, selected to the unit's environmental exposure and required creepage and clearance.

Certifications

  • EN 61558

Sub-series

  • EE20
  • EI30
  • EI38
  • EI42
  • EI48
  • EI54
  • EI60
  • EI66
An Aslan 10 VA EI48 PCB mount transformer, standard cover
Part numbers
1,164

940 in the current catalog, 224 discontinued

Power range
0.35–55 VA

0.35–220 VA including discontinued series

Secondary voltages
4–24 V

4, 6, 7.5, 9, 12, 15, 18, 24 V per winding, single or dual

Datasheets
83

One per series, free to download

Primary voltage: 230 V on every part in this family

These are 230 V mains transformers. There is no 115 V primary in the standard range, so a 120 V design needs a custom wind — which is normal business here, not an exception. Send us the input voltage you are designing to and we will confirm the winding.

Find a part number

Every part number in the family. Narrow by core, secondary voltage, winding count, cover style, or availability — then open the part for its full figures and datasheet.

1,164 rows — showing 1–100

PCB Mount Transformers — published specifications
ASL0901040.354 V87.5EE20Standard—Active
ASL0901060.356 V58.3EE20Standard—Active
ASL0901080.357.5 V47EE20Standard—Active
ASL0901090.359 V38.8EE20Standard—Active
ASL0901120.3512 V29.1EE20Standard—Active
ASL0901150.3515 V23.3EE20Standard—Active
ASL0901180.3518 V19.4EE20Standard—Active
ASL0901240.3524 V14.5EE20Standard—Active
ASL0902060.352 × 6 V29.1EE20Standard—Active
ASL0902080.352 × 7.5 V23EE20Standard—Active
ASL0902090.352 × 9 V19.4EE20Standard—Active
ASL0902120.352 × 12 V14.5EE20Standard—Active
ASL0902150.352 × 15 V11.6EE20Standard—Active
ASL0902180.352 × 18 V9.7EE20Standard—Active
ASL0902240.352 × 24 V7.3EE20Standard—Active
ASL0911040.54 V125EE20Standard—Active
ASL0911060.56 V83.3EE20Standard—Active
ASL0911080.57.5 V67EE20Standard—Active
ASL0911090.59 V55.5EE20Standard—Active
ASL0911120.512 V41.6EE20Standard—Active
ASL0911150.515 V33.3EE20Standard—Active
ASL0911180.518 V27.8EE20Standard—Active
ASL0911240.524 V20.8EE20Standard—Active
ASL0912060.52 × 6 V41.6EE20Standard—Active
ASL0912080.52 × 7.5 V33EE20Standard—Active
ASL0912090.52 × 9 V27.7EE20Standard—Active
ASL0912120.52 × 12 V20.8EE20Standard—Active
ASL0912150.52 × 15 V16.6EE20Standard—Active
ASL0912180.52 × 18 V13.8EE20Standard—Active
ASL0912240.52 × 24 V10.4EE20Standard—Active
ASL1011060.56 V83EI30Standard—Active
ASL1011080.57.5 V67EI30Standard—Active
ASL1011090.59 V55EI30Standard—Active
ASL1011120.512 V41EI30Standard—Active
ASL1011150.515 V33EI30Standard—Active
ASL1011180.518 V27.5EI30Standard—Active
ASL1011240.524 V20EI30Standard—Active
ASL1012060.52 × 6 V41EI30Standard—Active
ASL1012080.52 × 7.5 V33EI30Standard—Active
ASL1012090.52 × 9 V27.5EI30Standard—Active
ASL1012120.52 × 12 V20EI30Standard—Active
ASL1012150.52 × 15 V16.5EI30Standard—Active
ASL1012180.52 × 18 V13.8EI30Standard—Active
ASL1012240.52 × 24 V10.4EI30Standard—Active
ASL1015060.76 V117EI30Standard—Discontinued
ASL1015080.77.5 V93EI30Standard—Discontinued
ASL1015090.79 V77.7EI30Standard—Discontinued
ASL1015120.712 V58.3EI30Standard—Discontinued
ASL1015150.715 V46.6EI30Standard—Discontinued
ASL1015180.718 V38.8EI30Standard—Discontinued
ASL1015240.724 V29.2EI30Standard—Discontinued
ASL1016060.72 × 6 V58.3EI30Standard—Discontinued
ASL1016080.72 × 7.5 V46.5EI30Standard—Discontinued
ASL1016090.72 × 9 V38.8EI30Standard—Discontinued
ASL1016120.72 × 12 V29.2EI30Standard—Discontinued
ASL1016150.72 × 15 V23.3EI30Standard—Discontinued
ASL1016180.72 × 18 V19.4EI30Standard—Discontinued
ASL1016240.72 × 24 V14.6EI30Standard—Discontinued
ASL10810616 V166EI30Standard—Active
ASL10810817.5 V133EI30Standard—Active
ASL10810919 V111EI30Standard—Active
ASL108112112 V83.3EI30Standard—Active
ASL108115115 V66.6EI30Standard—Active
ASL108118118 V55.5EI30Standard—Active
ASL108124124 V41.6EI30Standard—Active
ASL10820612 × 6 V83EI30Standard—Active
ASL10820812 × 7.5 V66.5EI30Standard—Active
ASL10820912 × 9 V55.5EI30Standard—Active
ASL10821212 × 12 V41.6EI30Standard—Active
ASL10821512 × 15 V33.3EI30Standard—Active
ASL10821812 × 18 V27.7EI30Standard—Active
ASL10822412 × 24 V20.8EI30Standard—Active
ASL1021061.26 V200EI30Standard—Active
ASL1021081.27.5 V160EI30Standard—Active
ASL1021091.29 V133EI30Standard—Active
ASL1021121.212 V100EI30Standard—Active
ASL1021151.215 V80EI30Standard—Active
ASL1021181.218 V67EI30Standard—Active
ASL1021241.224 V50EI30Standard—Active
ASL1022061.22 × 6 V100EI30Standard—Active
ASL1022081.22 × 7.5 V80EI30Standard—Active
ASL1022091.22 × 9 V67EI30Standard—Active
ASL1022121.22 × 12 V50EI30Standard—Active
ASL1022151.22 × 15 V40EI30Standard—Active
ASL1022181.22 × 18 V33EI30Standard—Active
ASL1022241.22 × 24 V25EI30Standard—Active
ASL1091061.46 V233EI30Standard—Active
ASL1091081.47.5 V186EI30Standard—Active
ASL1091091.49 V155EI30Standard—Active
ASL1091121.412 V116EI30Standard—Active
ASL1091151.415 V93EI30Standard—Active
ASL1091181.418 V77EI30Standard—Active
ASL1091241.424 V58EI30Standard—Active
ASL1092061.42 × 6 V116.5EI30Standard—Active
ASL1092081.42 × 7.5 V93EI30Standard—Active
ASL1092091.42 × 9 V77.5EI30Standard—Active
ASL1092121.42 × 12 V58EI30Standard—Active
ASL1092151.42 × 15 V46.5EI30Standard—Active
ASL1092181.42 × 18 V38.8EI30Standard—Active
ASL1092241.42 × 24 V29EI30Standard—Active

Figures are reproduced from the factory datasheets linked below. Current is quoted per secondary winding, so a dual-winding part delivers the listed current on each of its two windings. Rows marked discontinued are kept for designs already using them and cannot be ordered.

EI78, EI84, EI96 have been withdrawn from the current catalog

224 of the part numbers above are discontinued and cannot be ordered. Their pages and datasheets stay published for anyone maintaining an existing design, and each one lists the active parts it can be requoted against where the range still reaches that rating.

The current range tops out at 55 VA. Above that we build to order — send the specification and we will quote the wind.

Datasheets

83 factory datasheets cover this family, one per series. Each gives the dimensions, winding table, and pin layout for the part numbers built on it — all of them hosted here, indexed below and linked from every part page.

Series and datasheets

Aslan publishes one datasheet per series — a core size, a rating, and a cover style, covering the part numbers wound on it. All 83 are hosted here.

EE20

0.35–0.5 VA · 2 datasheets

EI30

0.5–2.6 VA · 9 datasheets

EI38

2.5–5.4 VA · 7 datasheets

EI42

3–8 VA · 8 datasheets

EI48

10–15 VA · 10 datasheets

EI54

16–23 VA · 7 datasheets

EI60

25–35 VA · 14 datasheets

EI66

34–55 VA · 13 datasheets

EI78

55–80 VA · 3 datasheets

Core withdrawn

EI84

75–100 VA · 4 datasheets

Core withdrawn

EI96

140–220 VA · 6 datasheets

Core withdrawn

Typical applications

  • Isolated low-voltage supplies for control and instrumentation circuits
  • Signal and control transformers on industrial control boards
  • Battery-charger and small linear power-supply primaries
  • Lighting ballast and LED driver circuits
  • Metering and protective-relay isolation
  • Appliance and HVAC control electronics
  • Safety isolation for sensor and interface circuits

Next step

Not finding the exact part?

Three ways in, and each one arrives with PCB Mount Transformers already attached.

Cross-reference

Replacing a Würth, Coilcraft, Pulse, TDK, or Bourns part? Send us the part number.

Cross-reference a part

Custom build

Need a different power rating, size, or termination?

Start a custom inquiry

Samples

Qualifying a part before you commit to a build? Request samples for this family.

Request samples