Skip to content
S&B Tech

EE20 series

0.5VA-EE20-10.5

0.5 VA · EE20 core · Standard (0) · 230 V primary · 15 part numbers

Photograph of an Aslan 0.5VA-EE20-10.5 EE20 transformer
0.5VA-EE20-10.5 as supplied — Standard (0). The winding printed on the label is one of the part numbers listed below.
Dimensioned drawing of the 0.5VA-EE20-10.5 transformer: outline, mounting height, and pin layout
Outline and pin layout — millimetres. Every part number on the 0.5VA-EE20-10.5 datasheet shares this footprint.

Series specifications

Core
EE20
Rated power
0.5 VA
Primary
230 V (single winding)
Secondary
4–24 V per winding · single or dual
Winding code
10.5
Cover style
Standard (0)
Copper weight
8 g
Total weight
35 g
Pin configuration
1-4 / 6-7 · 1-4 / 5-6 + 7-8
Certifications
EN 61558
Part numbers
15 on this datasheet

Insulation and impregnation are specified as air, oven-dried varnish, polyurethane coating, or epoxy potting, selected to the unit's environmental exposure and required creepage and clearance.

Datasheet

Factory datasheet for the 0.5VA-EE20-10.5 series — dimensions, winding table, and pin layout for every part number on this page. PDF, opens in a new tab.

0.5VA-EE20-10.5.pdf

Part numbers in this series

Core, rating, cover, and footprint are fixed by the datasheet above. These 15 part numbers differ only in the secondary winding.

15 rows

0.5VA-EE20-10.5 — part numbers
ASL0911044 V1257.4 V1-4 / 6-7
ASL0911066 V83.310.8 V1-4 / 6-7
ASL0911087.5 V6712.7 V1-4 / 6-7
ASL0911099 V55.516.5 V1-4 / 6-7
ASL09111212 V41.620.6 V1-4 / 6-7
ASL09111515 V33.326 V1-4 / 6-7
ASL09111818 V27.830.1 V1-4 / 6-7
ASL09112424 V20.841.1 V1-4 / 6-7
ASL0912062 × 6 V41.610.9 V1-4 / 5-6 + 7-8
ASL0912082 × 7.5 V3312.7 V1-4 / 5-6 + 7-8
ASL0912092 × 9 V27.716.4 V1-4 / 5-6 + 7-8
ASL0912122 × 12 V20.820.6 V1-4 / 5-6 + 7-8
ASL0912152 × 15 V16.624.8 V1-4 / 5-6 + 7-8
ASL0912182 × 18 V13.828.9 V1-4 / 5-6 + 7-8
ASL0912242 × 24 V10.441.3 V1-4 / 5-6 + 7-8

Current is quoted per secondary winding, so a dual-winding part delivers the listed current on each of its two windings rather than splitting it between them. No-load voltage is the open-circuit secondary before the winding is loaded — expect it to sit above the rated figure.

Next step

Need a winding this datasheet does not cover?

Every part on this page is wound to order, so a secondary voltage, a cover style, or a footprint outside the standard table is a quote, not a refusal.