EE20 series
0.5VA-EE20-10.5
0.5 VA · EE20 core · Standard (0) · 230 V primary · 15 part numbers


Series specifications
- Core
- EE20
- Rated power
- 0.5 VA
- Primary
- 230 V (single winding)
- Secondary
- 4–24 V per winding · single or dual
- Winding code
- 10.5
- Cover style
- Standard (0)
- Copper weight
- 8 g
- Total weight
- 35 g
- Pin configuration
- 1-4 / 6-7 · 1-4 / 5-6 + 7-8
- Certifications
- EN 61558
- Part numbers
- 15 on this datasheet
Insulation and impregnation are specified as air, oven-dried varnish, polyurethane coating, or epoxy potting, selected to the unit's environmental exposure and required creepage and clearance.
Datasheet
Factory datasheet for the 0.5VA-EE20-10.5 series — dimensions, winding table, and pin layout for every part number on this page. PDF, opens in a new tab.
0.5VA-EE20-10.5.pdf
Part numbers in this series
Core, rating, cover, and footprint are fixed by the datasheet above. These 15 part numbers differ only in the secondary winding.
15 rows
| ASL091104 | 4 V | 125 | 7.4 V | 1-4 / 6-7 |
|---|---|---|---|---|
| ASL091106 | 6 V | 83.3 | 10.8 V | 1-4 / 6-7 |
| ASL091108 | 7.5 V | 67 | 12.7 V | 1-4 / 6-7 |
| ASL091109 | 9 V | 55.5 | 16.5 V | 1-4 / 6-7 |
| ASL091112 | 12 V | 41.6 | 20.6 V | 1-4 / 6-7 |
| ASL091115 | 15 V | 33.3 | 26 V | 1-4 / 6-7 |
| ASL091118 | 18 V | 27.8 | 30.1 V | 1-4 / 6-7 |
| ASL091124 | 24 V | 20.8 | 41.1 V | 1-4 / 6-7 |
| ASL091206 | 2 × 6 V | 41.6 | 10.9 V | 1-4 / 5-6 + 7-8 |
| ASL091208 | 2 × 7.5 V | 33 | 12.7 V | 1-4 / 5-6 + 7-8 |
| ASL091209 | 2 × 9 V | 27.7 | 16.4 V | 1-4 / 5-6 + 7-8 |
| ASL091212 | 2 × 12 V | 20.8 | 20.6 V | 1-4 / 5-6 + 7-8 |
| ASL091215 | 2 × 15 V | 16.6 | 24.8 V | 1-4 / 5-6 + 7-8 |
| ASL091218 | 2 × 18 V | 13.8 | 28.9 V | 1-4 / 5-6 + 7-8 |
| ASL091224 | 2 × 24 V | 10.4 | 41.3 V | 1-4 / 5-6 + 7-8 |
Current is quoted per secondary winding, so a dual-winding part delivers the listed current on each of its two windings rather than splitting it between them. No-load voltage is the open-circuit secondary before the winding is loaded — expect it to sit above the rated figure.
Next step
Need a winding this datasheet does not cover?
Every part on this page is wound to order, so a secondary voltage, a cover style, or a footprint outside the standard table is a quote, not a refusal.