Skip to content
S&B Tech

EI60 series

25VA-EI60-21-BO

25 VA · EI60 core · BO · 230 V primary · 14 part numbers

25VA-EI60-21-BO as supplied — BO.
Outline and pin layout — millimetres, 32.5 mm pin spacing. Every part number on the 25VA-EI60-21-BO datasheet shares this footprint.

Series specifications

Core
EI60
Rated power
25 VA
Primary
230 V (single winding)
Secondary
6–24 V per winding · single or dual
Pin spacing
32.5 mm
Winding code
21
Cover style
BO
Copper weight
110 g
Total weight
570 g
Pin configuration
1-7 / 9-13 · 1-7 / 8-9 + 13-14
Certifications
EN 61558
Part numbers
14 on this datasheet

Insulation and impregnation are specified as air, oven-dried varnish, polyurethane coating, or epoxy potting, selected to the unit's environmental exposure and required creepage and clearance.

Datasheet

Factory datasheet for the 25VA-EI60-21-BO series — dimensions, winding table, and pin layout for every part number on this page. PDF, opens in a new tab.

25VA-EI60-21-BO.pdf

Part numbers in this series

Core, rating, cover, and footprint are fixed by the datasheet above. These 14 part numbers differ only in the secondary winding.

14 rows

25VA-EI60-21-BO — part numbers
ASL180106BO6 V4,1667.3 V1-7 / 9-13
ASL180108BO7.5 V3,3359.1 V1-7 / 9-13
ASL180109BO9 V2,77710.8 V1-7 / 9-13
ASL180112BO12 V2,08314.4 V1-7 / 9-13
ASL180115BO15 V1,66618.1 V1-7 / 9-13
ASL180118BO18 V1,38821.4 V1-7 / 9-13
ASL180124BO24 V1,04128.7 V1-7 / 9-13
ASL180206BO2 × 6 V2,0837.3 V1-7 / 8-9 + 13-14
ASL180208BO2 × 7.5 V1,6689.1 V1-7 / 8-9 + 13-14
ASL180209BO2 × 9 V1,38810.8 V1-7 / 8-9 + 13-14
ASL180212BO2 × 12 V1,04114.4 V1-7 / 8-9 + 13-14
ASL180215BO2 × 15 V83318.1 V1-7 / 8-9 + 13-14
ASL180218BO2 × 18 V69421.4 V1-7 / 8-9 + 13-14
ASL180224BO2 × 24 V52029 V1-7 / 8-9 + 13-14

Current is quoted per secondary winding, so a dual-winding part delivers the listed current on each of its two windings rather than splitting it between them. No-load voltage is the open-circuit secondary before the winding is loaded — expect it to sit above the rated figure.

Next step

Need a winding this datasheet does not cover?

Every part on this page is wound to order, so a secondary voltage, a cover style, or a footprint outside the standard table is a quote, not a refusal.