EI30 series
1VA-EI30-8
1 VA · EI30 core · Standard (0) · 230 V primary · 14 part numbers


Series specifications
- Core
- EI30
- Rated power
- 1 VA
- Primary
- 230 V (single winding)
- Secondary
- 6–24 V per winding · single or dual
- Winding code
- 8
- Cover style
- Standard (0)
- Copper weight
- 11 g
- Total weight
- 55 g
- Pin configuration
- 1-5 / 7-9 · 1-5 / 6-7 + 9-10
- Certifications
- EN 61558
- Part numbers
- 14 on this datasheet
Insulation and impregnation are specified as air, oven-dried varnish, polyurethane coating, or epoxy potting, selected to the unit's environmental exposure and required creepage and clearance.
Datasheet
Factory datasheet for the 1VA-EI30-8 series — dimensions, winding table, and pin layout for every part number on this page. PDF, opens in a new tab.
1VA-EI30-8.pdf
Part numbers in this series
Core, rating, cover, and footprint are fixed by the datasheet above. These 14 part numbers differ only in the secondary winding.
14 rows
| ASL108106 | 6 V | 166 | 10.34 V | 1-5 / 7-9 |
|---|---|---|---|---|
| ASL108108 | 7.5 V | 133 | 13 V | 1-5 / 7-9 |
| ASL108109 | 9 V | 111 | 15.69 V | 1-5 / 7-9 |
| ASL108112 | 12 V | 83.3 | 20.8 V | 1-5 / 7-9 |
| ASL108115 | 15 V | 66.6 | 26.05 V | 1-5 / 7-9 |
| ASL108118 | 18 V | 55.5 | 31.9 V | 1-5 / 7-9 |
| ASL108124 | 24 V | 41.6 | 41.29 V | 1-5 / 7-9 |
| ASL108206 | 2 × 6 V | 83 | 10.25 V | 1-5 / 6-7 + 9-10 |
| ASL108208 | 2 × 7.5 V | 66.5 | 13 V | 1-5 / 6-7 + 9-10 |
| ASL108209 | 2 × 9 V | 55.5 | 15.4 V | 1-5 / 6-7 + 9-10 |
| ASL108212 | 2 × 12 V | 41.6 | 18.6 V | 1-5 / 6-7 + 9-10 |
| ASL108215 | 2 × 15 V | 33.3 | 24.4 V | 1-5 / 6-7 + 9-10 |
| ASL108218 | 2 × 18 V | 27.7 | 30 V | 1-5 / 6-7 + 9-10 |
| ASL108224 | 2 × 24 V | 20.8 | 39.8 V | 1-5 / 6-7 + 9-10 |
Current is quoted per secondary winding, so a dual-winding part delivers the listed current on each of its two windings rather than splitting it between them. No-load voltage is the open-circuit secondary before the winding is loaded — expect it to sit above the rated figure.
Next step
Need a winding this datasheet does not cover?
Every part on this page is wound to order, so a secondary voltage, a cover style, or a footprint outside the standard table is a quote, not a refusal.