Skip to content
S&B Tech

EI30 series

1VA-EI30-8

1 VA · EI30 core · Standard (0) · 230 V primary · 14 part numbers

Photograph of an Aslan 1VA-EI30-8 EI30 transformer
1VA-EI30-8 as supplied — Standard (0). The winding printed on the label is one of the part numbers listed below.
Dimensioned drawing of the 1VA-EI30-8 transformer: outline, mounting height, and pin layout
Outline and pin layout — millimetres. Every part number on the 1VA-EI30-8 datasheet shares this footprint.

Series specifications

Core
EI30
Rated power
1 VA
Primary
230 V (single winding)
Secondary
6–24 V per winding · single or dual
Winding code
8
Cover style
Standard (0)
Copper weight
11 g
Total weight
55 g
Pin configuration
1-5 / 7-9 · 1-5 / 6-7 + 9-10
Certifications
EN 61558
Part numbers
14 on this datasheet

Insulation and impregnation are specified as air, oven-dried varnish, polyurethane coating, or epoxy potting, selected to the unit's environmental exposure and required creepage and clearance.

Datasheet

Factory datasheet for the 1VA-EI30-8 series — dimensions, winding table, and pin layout for every part number on this page. PDF, opens in a new tab.

1VA-EI30-8.pdf

Part numbers in this series

Core, rating, cover, and footprint are fixed by the datasheet above. These 14 part numbers differ only in the secondary winding.

14 rows

1VA-EI30-8 — part numbers
ASL1081066 V16610.34 V1-5 / 7-9
ASL1081087.5 V13313 V1-5 / 7-9
ASL1081099 V11115.69 V1-5 / 7-9
ASL10811212 V83.320.8 V1-5 / 7-9
ASL10811515 V66.626.05 V1-5 / 7-9
ASL10811818 V55.531.9 V1-5 / 7-9
ASL10812424 V41.641.29 V1-5 / 7-9
ASL1082062 × 6 V8310.25 V1-5 / 6-7 + 9-10
ASL1082082 × 7.5 V66.513 V1-5 / 6-7 + 9-10
ASL1082092 × 9 V55.515.4 V1-5 / 6-7 + 9-10
ASL1082122 × 12 V41.618.6 V1-5 / 6-7 + 9-10
ASL1082152 × 15 V33.324.4 V1-5 / 6-7 + 9-10
ASL1082182 × 18 V27.730 V1-5 / 6-7 + 9-10
ASL1082242 × 24 V20.839.8 V1-5 / 6-7 + 9-10

Current is quoted per secondary winding, so a dual-winding part delivers the listed current on each of its two windings rather than splitting it between them. No-load voltage is the open-circuit secondary before the winding is loaded — expect it to sit above the rated figure.

Next step

Need a winding this datasheet does not cover?

Every part on this page is wound to order, so a secondary voltage, a cover style, or a footprint outside the standard table is a quote, not a refusal.