Skip to content
S&B Tech

EI66 series

55VA-EI66-34.7-BO

55 VA · EI66 core · BO · 230 V primary · 14 part numbers

55VA-EI66-34.7-BO as supplied — BO.
Outline and pin layout — millimetres, 35 mm pin spacing. Every part number on the 55VA-EI66-34.7-BO datasheet shares this footprint.

Series specifications

Core
EI66
Rated power
55 VA
Primary
230 V (single winding)
Secondary
6–24 V per winding · single or dual
Pin spacing
35 mm
Winding code
34.7
Cover style
BO
Copper weight
180 g
Total weight
1,080 g
Pin configuration
1-8 / 11-14 · 1-8 / 9-10 + 15-16
Certifications
EN 61558
Part numbers
14 on this datasheet

Insulation and impregnation are specified as air, oven-dried varnish, polyurethane coating, or epoxy potting, selected to the unit's environmental exposure and required creepage and clearance.

Datasheet

Factory datasheet for the 55VA-EI66-34.7-BO series — dimensions, winding table, and pin layout for every part number on this page. PDF, opens in a new tab.

55VA-EI66-34.7-BO.pdf

Part numbers in this series

Core, rating, cover, and footprint are fixed by the datasheet above. These 14 part numbers differ only in the secondary winding.

14 rows

55VA-EI66-34.7-BO — part numbers
ASL193106BO6 V9,1606.6 V1-8 / 11-14
ASL193108BO7.5 V7,3308.2 V1-8 / 11-14
ASL193109BO9 V6,1109.9 V1-8 / 11-14
ASL193112BO12 V4,58013.2 V1-8 / 11-14
ASL193115BO15 V3,66016.5 V1-8 / 11-14
ASL193118BO18 V3,05019.8 V1-8 / 11-14
ASL193124BO24 V2,29026.6 V1-8 / 11-14
ASL193206BO2 × 6 V4,5806.6 V1-8 / 9-10 + 15-16
ASL193208BO2 × 7.5 V3,6608.2 V1-8 / 9-10 + 15-16
ASL193209BO2 × 9 V3,05010 V1-8 / 9-10 + 15-16
ASL193212BO2 × 12 V2,29013.4 V1-8 / 9-10 + 15-16
ASL193215BO2 × 15 V1,83016.7 V1-8 / 9-10 + 15-16
ASL193218BO2 × 18 V1,52020 V1-8 / 9-10 + 15-16
ASL193224BO2 × 24 V1,14026.5 V1-8 / 9-10 + 15-16

Current is quoted per secondary winding, so a dual-winding part delivers the listed current on each of its two windings rather than splitting it between them. No-load voltage is the open-circuit secondary before the winding is loaded — expect it to sit above the rated figure.

Next step

Need a winding this datasheet does not cover?

Every part on this page is wound to order, so a secondary voltage, a cover style, or a footprint outside the standard table is a quote, not a refusal.