EI30 series
1.4VA-EI30-11.5
1.4 VA · EI30 core · Standard (0) · 230 V primary · 14 part numbers


Series specifications
- Core
- EI30
- Rated power
- 1.4 VA
- Primary
- 230 V (single winding)
- Secondary
- 6–24 V per winding · single or dual
- Winding code
- 11.5
- Cover style
- Standard (0)
- Copper weight
- 14 g
- Total weight
- 80 g
- Pin configuration
- 1-5 / 7-9 · 1-5 / 6-7 + 9-10
- Certifications
- EN 61558
- Part numbers
- 14 on this datasheet
Insulation and impregnation are specified as air, oven-dried varnish, polyurethane coating, or epoxy potting, selected to the unit's environmental exposure and required creepage and clearance.
Datasheet
Factory datasheet for the 1.4VA-EI30-11.5 series — dimensions, winding table, and pin layout for every part number on this page. PDF, opens in a new tab.
1.4VA-EI30-11.5.pdf
Part numbers in this series
Core, rating, cover, and footprint are fixed by the datasheet above. These 14 part numbers differ only in the secondary winding.
14 rows
| ASL109106 | 6 V | 233 | 9.9 V | 1-5 / 7-9 |
|---|---|---|---|---|
| ASL109108 | 7.5 V | 186 | 12.5 V | 1-5 / 7-9 |
| ASL109109 | 9 V | 155 | 15 V | 1-5 / 7-9 |
| ASL109112 | 12 V | 116 | 19.7 V | 1-5 / 7-9 |
| ASL109115 | 15 V | 93 | 24.8 V | 1-5 / 7-9 |
| ASL109118 | 18 V | 77 | 29.5 V | 1-5 / 7-9 |
| ASL109124 | 24 V | 58 | 38.7 V | 1-5 / 7-9 |
| ASL109206 | 2 × 6 V | 116.5 | 10 V | 1-5 / 6-7 + 9-10 |
| ASL109208 | 2 × 7.5 V | 93 | 12.5 V | 1-5 / 6-7 + 9-10 |
| ASL109209 | 2 × 9 V | 77.5 | 14.9 V | 1-5 / 6-7 + 9-10 |
| ASL109212 | 2 × 12 V | 58 | 19.7 V | 1-5 / 6-7 + 9-10 |
| ASL109215 | 2 × 15 V | 46.5 | 24.7 V | 1-5 / 6-7 + 9-10 |
| ASL109218 | 2 × 18 V | 38.8 | 29.33 V | 1-5 / 6-7 + 9-10 |
| ASL109224 | 2 × 24 V | 29 | 38.6 V | 1-5 / 6-7 + 9-10 |
Current is quoted per secondary winding, so a dual-winding part delivers the listed current on each of its two windings rather than splitting it between them. No-load voltage is the open-circuit secondary before the winding is loaded — expect it to sit above the rated figure.
Next step
Need a winding this datasheet does not cover?
Every part on this page is wound to order, so a secondary voltage, a cover style, or a footprint outside the standard table is a quote, not a refusal.