Skip to content
S&B Tech

EI66 series

45VA-EI66-30-BO

45 VA · EI66 core · BO · 230 V primary · 14 part numbers

45VA-EI66-30-BO as supplied — BO.
Outline and pin layout — millimetres, 35 mm pin spacing. Every part number on the 45VA-EI66-30-BO datasheet shares this footprint.

Series specifications

Core
EI66
Rated power
45 VA
Primary
230 V (single winding)
Secondary
6–24 V per winding · single or dual
Pin spacing
35 mm
Winding code
30
Cover style
BO
Copper weight
170 g
Total weight
950 g
Pin configuration
1-8 / 11-14 · 1-8 / 9-10 + 15-16
Certifications
EN 61558
Part numbers
14 on this datasheet

Insulation and impregnation are specified as air, oven-dried varnish, polyurethane coating, or epoxy potting, selected to the unit's environmental exposure and required creepage and clearance.

Datasheet

Factory datasheet for the 45VA-EI66-30-BO series — dimensions, winding table, and pin layout for every part number on this page. PDF, opens in a new tab.

45VA-EI66-30-BO.pdf

Part numbers in this series

Core, rating, cover, and footprint are fixed by the datasheet above. These 14 part numbers differ only in the secondary winding.

14 rows

45VA-EI66-30-BO — part numbers
ASL192106BO6 V7,5006.8 V1-8 / 11-14
ASL192108BO7.5 V6,0008.7 V1-8 / 11-14
ASL192109BO9 V5,00010.2 V1-8 / 11-14
ASL192112BO12 V3,75013.9 V1-8 / 11-14
ASL192115BO15 V3,00017.15 V1-8 / 11-14
ASL192118BO18 V2,50020.45 V1-8 / 11-14
ASL192124BO24 V1,88026.9 V1-8 / 11-14
ASL192206BO2 × 6 V3,7506.8 V1-8 / 9-10 + 15-16
ASL192208BO2 × 7.5 V3,0008.7 V1-8 / 9-10 + 15-16
ASL192209BO2 × 9 V2,50010.51 V1-8 / 9-10 + 15-16
ASL192212BO2 × 12 V1,88013.8 V1-8 / 9-10 + 15-16
ASL192215BO2 × 15 V1,50017.15 V1-8 / 9-10 + 15-16
ASL192218BO2 × 18 V1,25020.85 V1-8 / 9-10 + 15-16
ASL192224BO2 × 24 V94027.25 V1-8 / 9-10 + 15-16

Current is quoted per secondary winding, so a dual-winding part delivers the listed current on each of its two windings rather than splitting it between them. No-load voltage is the open-circuit secondary before the winding is loaded — expect it to sit above the rated figure.

Next step

Need a winding this datasheet does not cover?

Every part on this page is wound to order, so a secondary voltage, a cover style, or a footprint outside the standard table is a quote, not a refusal.