S&B Tech

EI48 series

10VA-EI48-16.8-BO

10 VA · EI48 core · BO · 230 V primary · 14 part numbers

10VA-EI48-16.8-BO as supplied — BO.
Outline and pin layout — millimetres, 27.5 mm pin spacing. Every part number on the 10VA-EI48-16.8-BO datasheet shares this footprint.

Series specifications

Core
EI48
Rated power
10 VA
Primary
230 V (single winding)
Secondary
6–24 V per winding · single or dual
Pin spacing
27.5 mm
Winding code
16.8
Cover style
BO
Copper weight
50 g
Total weight
275 g
Pin configuration
1-6 / 8-11 · 1-6 / 7-8 + 11-12
Certifications
EN 61558
Part numbers
14 on this datasheet

Insulation and impregnation are specified as air, oven-dried varnish, polyurethane coating, or epoxy potting, selected to the unit's environmental exposure and required creepage and clearance.

Datasheet

Factory datasheet for the 10VA-EI48-16.8-BO series — dimensions, winding table, and pin layout for every part number on this page. PDF, opens in a new tab.

10VA-EI48-16.8-BO.pdf

Part numbers in this series

Core, rating, cover, and footprint are fixed by the datasheet above. These 14 part numbers differ only in the secondary winding.

14 rows

10VA-EI48-16.8-BO — part numbers
ASL160106BO6 V1,6667.4 V1-6 / 8-11
ASL160108BO7.5 V1,3329.6 V1-6 / 8-11
ASL160109BO9 V1,11111.3 V1-6 / 8-11
ASL160112BO12 V83315.1 V1-6 / 8-11
ASL160115BO15 V66618.8 V1-6 / 8-11
ASL160118BO18 V55522.6 V1-6 / 8-11
ASL160124BO24 V41629.1 V1-6 / 8-11
ASL160206BO2 × 6 V8337.5 V1-6 / 7-8 + 11-12
ASL160208BO2 × 7.5 V6669.6 V1-6 / 7-8 + 11-12
ASL160209BO2 × 9 V55511.3 V1-6 / 7-8 + 11-12
ASL160212BO2 × 12 V41615 V1-6 / 7-8 + 11-12
ASL160215BO2 × 15 V33318.9 V1-6 / 7-8 + 11-12
ASL160218BO2 × 18 V27722.5 V1-6 / 7-8 + 11-12
ASL160224BO2 × 24 V20829 V1-6 / 7-8 + 11-12

Current is quoted per secondary winding, so a dual-winding part delivers the listed current on each of its two windings rather than splitting it between them. No-load voltage is the open-circuit secondary before the winding is loaded — expect it to sit above the rated figure.

Next step

Need a winding this datasheet does not cover?

Every part on this page is wound to order, so a secondary voltage, a cover style, or a footprint outside the standard table is a quote, not a refusal.