Skip to content
S&B Tech

EI42 series

5VA-EI42-14.8-BO

5 VA · EI42 core · BO · 230 V primary · 14 part numbers

5VA-EI42-14.8-BO as supplied — BO.
Outline and pin layout — millimetres, 25 mm pin spacing. Every part number on the 5VA-EI42-14.8-BO datasheet shares this footprint.

Series specifications

Core
EI42
Rated power
5 VA
Primary
230 V (single winding)
Secondary
6–24 V per winding · single or dual
Pin spacing
25 mm
Winding code
14.8
Cover style
BO
Copper weight
30 g
Total weight
190 g
Pin configuration
1-6 / 8-11 · 1-6 / 7-8 + 11-12
Certifications
EN 61558
Part numbers
14 on this datasheet

Insulation and impregnation are specified as air, oven-dried varnish, polyurethane coating, or epoxy potting, selected to the unit's environmental exposure and required creepage and clearance.

Datasheet

Factory datasheet for the 5VA-EI42-14.8-BO series — dimensions, winding table, and pin layout for every part number on this page. PDF, opens in a new tab.

5VA-EI42-14.8-BO.pdf

Part numbers in this series

Core, rating, cover, and footprint are fixed by the datasheet above. These 14 part numbers differ only in the secondary winding.

14 rows

5VA-EI42-14.8-BO — part numbers
ASL150106BO6 V8337.9 V1-6 / 8-11
ASL150108BO7.5 V6669.9 V1-6 / 8-11
ASL150109BO9 V55511.9 V1-6 / 8-11
ASL150112BO12 V41615.8 V1-6 / 8-11
ASL150115BO15 V33319.8 V1-6 / 8-11
ASL150118BO18 V27724.1 V1-6 / 8-11
ASL150124BO24 V20831.3 V1-6 / 8-11
ASL150206BO2 × 6 V4167.8 V1-6 / 7-8 + 11-12
ASL150208BO2 × 7.5 V3339.7 V1-6 / 7-8 + 11-12
ASL150209BO2 × 9 V27711.7 V1-6 / 7-8 + 11-12
ASL150212BO2 × 12 V20815.4 V1-6 / 7-8 + 11-12
ASL150215BO2 × 15 V16619.3 V1-6 / 7-8 + 11-12
ASL150218BO2 × 18 V13823.1 V1-6 / 7-8 + 11-12
ASL150224BO2 × 24 V10430.6 V1-6 / 7-8 + 11-12

Current is quoted per secondary winding, so a dual-winding part delivers the listed current on each of its two windings rather than splitting it between them. No-load voltage is the open-circuit secondary before the winding is loaded — expect it to sit above the rated figure.

Next step

Need a winding this datasheet does not cover?

Every part on this page is wound to order, so a secondary voltage, a cover style, or a footprint outside the standard table is a quote, not a refusal.