Skip to content
S&B Tech

EI54 series

16VA-EI54-18.8-BO

16 VA · EI54 core · BO · 230 V primary · 14 part numbers

16VA-EI54-18.8-BO as supplied — BO.
Outline and pin layout — millimetres, 30 mm pin spacing. Every part number on the 16VA-EI54-18.8-BO datasheet shares this footprint.

Series specifications

Core
EI54
Rated power
16 VA
Primary
230 V (single winding)
Secondary
6–24 V per winding · single or dual
Pin spacing
30 mm
Winding code
18.8
Cover style
BO
Copper weight
80 g
Total weight
417 g
Pin configuration
1-7 / 9-13 · 1-7 / 8-9 + 13-14
Certifications
EN 61558
Part numbers
14 on this datasheet

Insulation and impregnation are specified as air, oven-dried varnish, polyurethane coating, or epoxy potting, selected to the unit's environmental exposure and required creepage and clearance.

Datasheet

Factory datasheet for the 16VA-EI54-18.8-BO series — dimensions, winding table, and pin layout for every part number on this page. PDF, opens in a new tab.

16VA-EI54-18.8-BO.pdf

Part numbers in this series

Core, rating, cover, and footprint are fixed by the datasheet above. These 14 part numbers differ only in the secondary winding.

14 rows

16VA-EI54-18.8-BO — part numbers
ASL170106BO6 V2,6667.53 V1-7 / 9-13
ASL170108BO7.5 V2,1339.1 V1-7 / 9-13
ASL170109BO9 V1,77711.25 V1-7 / 9-13
ASL170112BO12 V1,33314.95 V1-7 / 9-13
ASL170115BO15 V1,06618.65 V1-7 / 9-13
ASL170118BO18 V88821.75 V1-7 / 9-13
ASL170124BO24 V66629.5 V1-7 / 9-13
ASL170206BO2 × 6 V1,3337.53 V1-7 / 8-9 + 13-14
ASL170208BO2 × 7.5 V1,0669.35 V1-7 / 8-9 + 13-14
ASL170209BO2 × 9 V88811.2 V1-7 / 8-9 + 13-14
ASL170212BO2 × 12 V66614.9 V1-7 / 8-9 + 13-14
ASL170215BO2 × 15 V53318.4 V1-7 / 8-9 + 13-14
ASL170218BO2 × 18 V44422.3 V1-7 / 8-9 + 13-14
ASL170224BO2 × 24 V33329.3 V1-7 / 8-9 + 13-14

Current is quoted per secondary winding, so a dual-winding part delivers the listed current on each of its two windings rather than splitting it between them. No-load voltage is the open-circuit secondary before the winding is loaded — expect it to sit above the rated figure.

Next step

Need a winding this datasheet does not cover?

Every part on this page is wound to order, so a secondary voltage, a cover style, or a footprint outside the standard table is a quote, not a refusal.