Skip to content
S&B Tech

UI48 series

50VA-UI48-17

50 VA · UI48 core · Standard (0) · 2 × 115 V primary · 7 part numbers

This series has been withdrawn from the current catalog

The 50VA-UI48-17 datasheet is no longer part of low-profile transformers production and these part numbers cannot be ordered. The page and the drawing stay published for anyone maintaining a design that already uses one — open a part number below to see the active parts it can be requoted against.

Send the specification and we will quote the same wind as a custom build.

Photograph of an Aslan 50VA-UI48-17 UI48 transformer
50VA-UI48-17 as supplied — Standard (0). The winding printed on the label is one of the part numbers listed below.
Dimensioned drawing of the 50VA-UI48-17 transformer: outline, mounting height, and pin layout
Outline and pin layout — millimetres. Every part number on the 50VA-UI48-17 datasheet shares this footprint.

Series specifications

Core
UI48
Rated power
50 VA
Primary
2 × 115 V (2 windings)
Secondary
6–24 V per winding · dual winding
Winding code
17
Cover style
Standard (0)
Copper weight
170 g
Total weight
800 g
Pin configuration
1-4 + 9-12 / 14-17 + 20-23
Certifications
EN 61558
Part numbers
7 on this datasheet

Insulation and impregnation are specified as air, oven-dried varnish, polyurethane coating, or epoxy potting, selected to the unit's environmental exposure and required creepage and clearance.

Datasheet

Archive copy

Factory datasheet for the withdrawn 50VA-UI48-17 series, kept here for anyone maintaining a design that already uses one. PDF, opens in a new tab.

50VA-UI48-17.pdf

Part numbers in this series

Core, rating, cover, and footprint are fixed by the datasheet above. These 7 part numbers differ only in the secondary winding.

7 rows

50VA-UI48-17 — part numbers
ASL6714062 × 6 V3,7506.6 V1-4 + 9-12 / 14-17 + 20-23
ASL6714082 × 7.5 V3,0008.4 V1-4 + 9-12 / 14-17 + 20-23
ASL6714092 × 9 V2,5009.85 V1-4 + 9-12 / 14-17 + 20-23
ASL6714122 × 12 V1,87513.1 V1-4 + 9-12 / 14-17 + 20-23
ASL6714152 × 15 V1,50016.4 V1-4 + 9-12 / 14-17 + 20-23
ASL6714182 × 18 V1,25019.9 V1-4 + 9-12 / 14-17 + 20-23
ASL6714242 × 24 V1,04126.5 V1-4 + 9-12 / 14-17 + 20-23

Current is quoted per secondary winding, so a dual-winding part delivers the listed current on each of its two windings rather than splitting it between them. No-load voltage is the open-circuit secondary before the winding is loaded — expect it to sit above the rated figure.

Next step

Still using this series?

The wind still exists as a specification even though the part number has gone. Send it over and we will price the same transformer as a custom build.