UI48 series
65VA-UI48-26
65 VA · UI48 core · Standard (0) · 2 × 115 V primary · 7 part numbers
This series has been withdrawn from the current catalog
The 65VA-UI48-26 datasheet is no longer part of low-profile transformers production and these part numbers cannot be ordered. The page and the drawing stay published for anyone maintaining a design that already uses one — open a part number below to see the active parts it can be requoted against.
Send the specification and we will quote the same wind as a custom build.


Series specifications
- Core
- UI48
- Rated power
- 65 VA
- Primary
- 2 × 115 V (2 windings)
- Secondary
- 6–24 V per winding · dual winding
- Winding code
- 26
- Cover style
- Standard (0)
- Copper weight
- 190 g
- Total weight
- 1,100 g
- Pin configuration
- 1-4 + 9-12 / 14-17 + 20-23
- Certifications
- EN 61558
- Part numbers
- 7 on this datasheet
Insulation and impregnation are specified as air, oven-dried varnish, polyurethane coating, or epoxy potting, selected to the unit's environmental exposure and required creepage and clearance.
Datasheet
Archive copyFactory datasheet for the withdrawn 65VA-UI48-26 series, kept here for anyone maintaining a design that already uses one. PDF, opens in a new tab.
65VA-UI48-26.pdf
Part numbers in this series
Core, rating, cover, and footprint are fixed by the datasheet above. These 7 part numbers differ only in the secondary winding.
7 rows
| ASL672406 | 2 × 6 V | 5,417 | 6.5 V | 1-4 + 9-12 / 14-17 + 20-23 |
|---|---|---|---|---|
| ASL672408 | 2 × 7.5 V | 4,333 | 8.3 V | 1-4 + 9-12 / 14-17 + 20-23 |
| ASL672409 | 2 × 9 V | 3,611 | 10.1 V | 1-4 + 9-12 / 14-17 + 20-23 |
| ASL672412 | 2 × 12 V | 2,708 | 13 V | 1-4 + 9-12 / 14-17 + 20-23 |
| ASL672415 | 2 × 15 V | 2,167 | 16.95 V | 1-4 + 9-12 / 14-17 + 20-23 |
| ASL672418 | 2 × 18 V | 1,806 | 19.9 V | 1-4 + 9-12 / 14-17 + 20-23 |
| ASL672424 | 2 × 24 V | 1,350 | 26.5 V | 1-4 + 9-12 / 14-17 + 20-23 |
Current is quoted per secondary winding, so a dual-winding part delivers the listed current on each of its two windings rather than splitting it between them. No-load voltage is the open-circuit secondary before the winding is loaded — expect it to sit above the rated figure.
Next step
Still using this series?
The wind still exists as a specification even though the part number has gone. Send it over and we will price the same transformer as a custom build.