Skip to content
S&B Tech

UI30 series

4VA-UI30-7.5

4 VA · UI30 core · Standard (0) · 2 × 115 V primary · 7 part numbers

Photograph of an Aslan 4VA-UI30-7.5 UI30 transformer
4VA-UI30-7.5 as supplied — Standard (0). The winding printed on the label is one of the part numbers listed below.
Dimensioned drawing of the 4VA-UI30-7.5 transformer: outline, mounting height, and pin layout
Outline and pin layout — millimetres. Every part number on the 4VA-UI30-7.5 datasheet shares this footprint.

Series specifications

Core
UI30
Rated power
4 VA
Primary
2 × 115 V (2 windings)
Secondary
6–24 V per winding · dual winding
Winding code
7.5
Cover style
Standard (0)
Copper weight
50 g
Total weight
150 g
Pin configuration
1-3 + 6-8 / 9-10 + 15-16
Certifications
EN 61558
Part numbers
7 on this datasheet

Insulation and impregnation are specified as air, oven-dried varnish, polyurethane coating, or epoxy potting, selected to the unit's environmental exposure and required creepage and clearance.

Datasheet

Factory datasheet for the 4VA-UI30-7.5 series — dimensions, winding table, and pin layout for every part number on this page. PDF, opens in a new tab.

4VA-UI30-7.5.pdf

Part numbers in this series

Core, rating, cover, and footprint are fixed by the datasheet above. These 7 part numbers differ only in the secondary winding.

7 rows

4VA-UI30-7.5 — part numbers
ASL6212062 × 6 V3339.2 V1-3 + 6-8 / 9-10 + 15-16
ASL6212082 × 7.5 V26611.4 V1-3 + 6-8 / 9-10 + 15-16
ASL6212092 × 9 V22213.7 V1-3 + 6-8 / 9-10 + 15-16
ASL6212122 × 12 V16617.9 V1-3 + 6-8 / 9-10 + 15-16
ASL6212152 × 15 V13322.4 V1-3 + 6-8 / 9-10 + 15-16
ASL6212182 × 18 V11124 V1-3 + 6-8 / 9-10 + 15-16
ASL6212242 × 24 V8335.4 V1-3 + 6-8 / 9-10 + 15-16

Current is quoted per secondary winding, so a dual-winding part delivers the listed current on each of its two windings rather than splitting it between them. No-load voltage is the open-circuit secondary before the winding is loaded — expect it to sit above the rated figure.

Next step

Need a winding this datasheet does not cover?

Every part on this page is wound to order, so a secondary voltage, a cover style, or a footprint outside the standard table is a quote, not a refusal.