Skip to content
S&B Tech

UI30 series

6VA-UI30-10.5

6 VA · UI30 core · Standard (0) · 2 × 115 V primary · 7 part numbers

Photograph of an Aslan 6VA-UI30-10.5 UI30 transformer
6VA-UI30-10.5 as supplied — Standard (0). The winding printed on the label is one of the part numbers listed below.
Dimensioned drawing of the 6VA-UI30-10.5 transformer: outline, mounting height, and pin layout
Outline and pin layout — millimetres. Every part number on the 6VA-UI30-10.5 datasheet shares this footprint.

Series specifications

Core
UI30
Rated power
6 VA
Primary
2 × 115 V (2 windings)
Secondary
6–24 V per winding · dual winding
Winding code
10.5
Cover style
Standard (0)
Copper weight
60 g
Total weight
180 g
Pin configuration
1-3 + 6-8 / 9-10 + 15-16
Certifications
EN 61558
Part numbers
7 on this datasheet

Insulation and impregnation are specified as air, oven-dried varnish, polyurethane coating, or epoxy potting, selected to the unit's environmental exposure and required creepage and clearance.

Datasheet

Factory datasheet for the 6VA-UI30-10.5 series — dimensions, winding table, and pin layout for every part number on this page. PDF, opens in a new tab.

6VA-UI30-10.5.pdf

Part numbers in this series

Core, rating, cover, and footprint are fixed by the datasheet above. These 7 part numbers differ only in the secondary winding.

7 rows

6VA-UI30-10.5 — part numbers
ASL6222062 × 6 V5008.4 V1-3 + 6-8 / 9-10 + 15-16
ASL6222082 × 7.5 V40010.4 V1-3 + 6-8 / 9-10 + 15-16
ASL6222092 × 9 V33312.4 V1-3 + 6-8 / 9-10 + 15-16
ASL6222122 × 12 V25016.3 V1-3 + 6-8 / 9-10 + 15-16
ASL6222152 × 15 V20020.3 V1-3 + 6-8 / 9-10 + 15-16
ASL6222182 × 18 V16623.8 V1-3 + 6-8 / 9-10 + 15-16
ASL6222242 × 24 V12531.9 V1-3 + 6-8 / 9-10 + 15-16

Current is quoted per secondary winding, so a dual-winding part delivers the listed current on each of its two windings rather than splitting it between them. No-load voltage is the open-circuit secondary before the winding is loaded — expect it to sit above the rated figure.

Next step

Need a winding this datasheet does not cover?

Every part on this page is wound to order, so a secondary voltage, a cover style, or a footprint outside the standard table is a quote, not a refusal.