Skip to content
S&B Tech

UI39 series

14VA-UI39-10.2

14 VA · UI39 core · Standard (0) · 2 × 115 V primary · 7 part numbers

Photograph of an Aslan 14VA-UI39-10.2 UI39 transformer
14VA-UI39-10.2 as supplied — Standard (0). The winding printed on the label is one of the part numbers listed below.
Dimensioned drawing of the 14VA-UI39-10.2 transformer: outline, mounting height, and pin layout
Outline and pin layout — millimetres. Every part number on the 14VA-UI39-10.2 datasheet shares this footprint.

Series specifications

Core
UI39
Rated power
14 VA
Primary
2 × 115 V (2 windings)
Secondary
6–24 V per winding · dual winding
Winding code
10.2
Cover style
Standard (0)
Copper weight
130 g
Total weight
320 g
Pin configuration
1-4 + 7-10 / 11-13 + 18-20
Certifications
EN 61558
Part numbers
7 on this datasheet

Insulation and impregnation are specified as air, oven-dried varnish, polyurethane coating, or epoxy potting, selected to the unit's environmental exposure and required creepage and clearance.

Datasheet

Factory datasheet for the 14VA-UI39-10.2 series — dimensions, winding table, and pin layout for every part number on this page. PDF, opens in a new tab.

14VA-UI39-10.2.pdf

Part numbers in this series

Core, rating, cover, and footprint are fixed by the datasheet above. These 7 part numbers differ only in the secondary winding.

7 rows

14VA-UI39-10.2 — part numbers
ASL6512062 × 6 V1,1667.2 V1-4 + 7-10 / 11-13 + 18-20
ASL6512082 × 7.5 V9339 V1-4 + 7-10 / 11-13 + 18-20
ASL6512092 × 9 V77710.6 V1-4 + 7-10 / 11-13 + 18-20
ASL6512122 × 12 V58313.9 V1-4 + 7-10 / 11-13 + 18-20
ASL6512152 × 15 V46617.8 V1-4 + 7-10 / 11-13 + 18-20
ASL6512182 × 18 V38821 V1-4 + 7-10 / 11-13 + 18-20
ASL6512242 × 24 V29128.6 V1-4 + 7-10 / 11-13 + 18-20

Current is quoted per secondary winding, so a dual-winding part delivers the listed current on each of its two windings rather than splitting it between them. No-load voltage is the open-circuit secondary before the winding is loaded — expect it to sit above the rated figure.

Next step

Need a winding this datasheet does not cover?

Every part on this page is wound to order, so a secondary voltage, a cover style, or a footprint outside the standard table is a quote, not a refusal.